Maintaining the SCOPIA Elite 5100 Series MCU | 37
RADVISION | Administrator Guide for SCOPIA Elite 5100 Series MCU Version 7.7
Step 4 Select Execute.
Note: After selecting Execute, a warning message appears, notifying you that the unit will be
reset and any active conferences will be disconnected.
Step 5 Select Yes to continue.
Step 6 Select Close.
Note: After applying the new port value, you must enter it as a suffix to the MCU IP address in
order to access the web server.
For example, if your new HTTP port value is 8080, access the web server by entering the
following:
http://<URL>:8080
Configuring the UDP Port for RAS on the SCOPIA Elite MCU
The SCOPIA Elite MCU 5000 Series has designated port 1719 for RAS. You can configure a different
port to use RAS (for example, if port 1719 is busy). Port 1719 is also used to communicate with
the gatekeeper (to configure the UDP port for the gatekeeper, see “Configuring the UDP Port for
the Gatekeeper on the SCOPIA Elite MCU” on page 38).
Note: If you close port 1719, you must configure another port for both RAS and the gatekeeper. If you
configure a different port for RAS, you do not need to configure a different port for the gatekeeper.
Procedure
Step 1 Navigate to the MCU Advanced Commands section by doing the following:
a. Select the icon.
b. Select Advanced parameters.
c. Locate the H323 RAS port number in the Name column (see Figure 3-29 on page 38).