Supporting ISDN Connectivity
The SCOPIA XT Series supports ISDN connectivity, allowing calls from endpoints to be routed to
the relevant conference using the SCOPIA BRI (Basic Rate Interface) and PRI (Primary Rate
Interface) gateways.
RADVISION has implemented a special pairing mechanism between the gateway and the
endpoint so that ISDN dialing is very simple. After pairing the systems, the participants place
ISDN calls by dialing the remote party ISDN number. The system automatically and
transparently takes care of setting the bit rate and call routing through the ISDN gateway.
A single gateway can serve multiple endpoints. For example, an organization needs to enable
5 endpoints with ISDN connectivity. Assuming the requested ISDN connectivity speed is
256bps, use only one ISDN PRI gateway as it can support 5 concurrent calls of 256bps each.
With the gateway approach less communication lines are needed. As all gateways do not
connect at the same time and not all calls are ISDN, many more endpoints can share the same
ISDN connection and gateway.
Implementing External API Control
You can control the XT Codec Unit using the SCOPIA XT Series API (requires integration with
AMX, Creston, or Extron control devices). Contact RADVISION customer support to receive the
Reference Guide for SCOPIA XT Series API, which includes the list of commands over the
Ethernet interface.
Implementing Port Security for the SCOPIA XT Series
The SCOPIA XT Series provides video technology for room conferencing, including support for
dual stream 1080p video, high quality data sharing, high quality full band audio and a high
capacity embedded MCU.
This section details the ports used for the SCOPIA XT Series and the relevant configuration
procedures:
Ports to Open on the SCOPIA XT Series.................................................. page 14
Configuring the TCP or UDP Port Range on the SCOPIA XT Series .................... page 18
Ports to Open on the SCOPIA XT Series
The SCOPIA XT Series is typically located in the enterprise network and is connected to the
DMZ. When opening ports to and from the SCOPIA XT Series, use the following as a reference:
If you are opening ports that are both to and from the SCOPIA XT Series, see Table 2-2 on
page 16.
If you are opening outbound ports from the SCOPIA XT Series, see Table 2-3 on page 18.
RADVISION | Installation Guide for SCOPIA XT5000 Series Version 3.1 Planning the Topology of the SCOPIA XT Series Deployment | 14