RADVision Scopia Elite 5100 Series Installation Guide Page 42

  • Download
  • Add to my manuals
  • Print
  • Page
    / 57
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 41
Performing the MCU Initial Configuration | 38
RADVISION | Installation Guide for SCOPIA Elite 5100 Series MCU Version 7.7
Step 5 Select Locate automatically to instruct the MCU to automatically locate one of the SIP servers
that are present in the domain,
or
Select Specify and enter the following:
An IP address or host name of the SIP server, for example <sipserver>.<company>.com.
Figure 5-7 SIP Protocol section of the Protocols tab
The communication port number of the SIP server address. The default port is 5060.
The transport connection type.
The default is UDP.
Figure 5-8 Type list
Note: The Locate automatically option works only if you have configured a valid IP address at
Configuration > Setup > Network > DNS server1 or DNS server2.
Step 6 To instruct the MCU to register with a SIP registrar and to send service information to the
registrar, perform these steps:
a. Select Use registrar.